To determination organic compounds in landfill leachates, the landfill leachates were extracted with a PT-C18 column and the extraction liquid were analyzed with a gas chromatograph coupled to an mass-selective detector(GC-MS). The results showed that total 162 kinds organic compounds been determinted out. One of them, there are 22 kinds of chinese priority pollutants and 32 kinds united states environmental protection agency priority pollutants.So solid-phase microextraction coupled with GC/MS was a fast and reliable method for the determination organic compounds in landfill leachates.

landfill leachates organic compounds solid-phase microeztraction gas chromatographic

Zhang Wen-Ye Zhang Hong-Zong