Solid Mass Fluz Measurement of the Gas-Solid Flow Using the Elbow-Ultrasonic

Solid mass flux measurement method of the gas-solid flow by the Elbow-Ultrasonic is brought out in this paper, it based on the elbow solid mass flux measurement method and the Ultrasonic velocity measurement method. The novel method neednot pre-required knowledge about the gas-solid flow density. The experiment system is built and experiments by mixing the coal powder with gas as test material are performed on the 80 mm test facility. The accuracy is studied by comparing the flow measured by Elbow-Ultrasonic with it by weighbridge. The experiment results prove that this method is feasible.

elbow Ultrasonic solid mass fluz gas-solid flow

Zhao Yanjun Shi Xinyue Wang Shimin

College of Computer and Automatic Control,Hebei Polytechnic University Tangshan,China The Key Laboratory of Clean Coal Power Generation and Combustion Technology Ministry of Education So