会议专题

Sensor-less Jam Fault Detection of Electro-hydraulic Ezecutive Device under Interval-valued Intuitionistic Fuzzy Circumstance

This paper presents a novel jam fault diagnosis method for electro-hydraulic executive device of steam turbine based on electro-reflection and intervalvalued intuitionistic fussy sets (IVIFSs) theory. Theoretical analysis and modeling research are conducted to reveal the relationship between jam fault and the peak to-peak value of the oscillation current (PVOC). Then we constructed a proportional valve load simulation device to carry out experimental and model based research. The results show that the variation of PVOC changes non-monotonically when jam fault occurs and thus has a characteristic of uncertain and interval valued. To overcome the problem, the concept of lVIFS is introduced, and the distance between two IVIFSs is defined. Then, the similarity degree between the detected variation of PVOC and the knowledge of jam fault is evaluated. The level of jam fault is determined according to the similarity degree.

Weibo Lee HongWei Shen

Department of Mechatronics Engineering,Shaoxing College of Arts and Sciences,508 Huancheng West Road Department of Steering,Shaoxing College of Arts and Sciences,508 Huancheng West Road,Shaoxing,Zhejia

国际会议

2009 International Conference on Measuring Technology and Mechatronics Automation(ICMTMA 2009)(2009年检测技术与机械自动化国际会议)

长沙

英文

1538-1541

2009-04-11(万方平台首次上网日期,不代表论文的发表时间)