会议专题

Test Method Research of Magnetic Saturation Current of High-frequency Transformer

When the case of magnetic saturation of high-frequency transformer occurs in switching power supply, the effect to efficiency and output power as well as the harm to power switch tube are analyzed. A method of lowvoltage, low-frequency square wave signal driving the primary coil of high-frequency transformer is introduced. By observing the current waveform of coil with oscilloscope and some following simple calculation, high-frequency magnetic transformer saturation current value can be obtained. The principle, related circuit, specific method, an example and result analysis of measuring are presented.

magnetic staturation high-frequency transformer test method

Hongtao Ma Xiaojun Wang Fenping Zhou

College of Information Science & Engineering Hebei University of Science & Technology Shijiazhuang,China

国际会议

2009 International Conference on Measuring Technology and Mechatronics Automation(ICMTMA 2009)(2009年检测技术与机械自动化国际会议)

长沙

英文

1656-1658

2009-04-11(万方平台首次上网日期,不代表论文的发表时间)