会议专题

Reversible Electroporation on a Microchip

The efficiency of electroporation for the porcine aortic endothelial valve cells is studied using pulsed dc electric fields and a new microchip applicator. The results indicate that maximum electroporation efficiency of over 80% can be achieved by choosing a proper amplitude and number of pulses. The result shows that increased field strength provides higher electroporation efficiency and maintains high cell viability within a limited value of applied electric charge. Our study also shows that the electroporation is reversible when the electric field is within 1 kV/cm.

H.S.Kim H.B.Kim J.H.Yi

Department of Biomedical Engineering,Konkuk University,Republic of Korea Solco Biomedical Institute,Republic of Korea

国际会议

Progress in Electromagnetics Research Symposium 2009(2009年电磁学研究新进展学术研讨会)(PIERS 2009)

北京

英文

1509-1512

2009-03-23(万方平台首次上网日期,不代表论文的发表时间)