Feeder Automation Modeling in IEC61850
Feeder Automation is one important parts of Distribution Automation. Considering that frequent change of network due to rapid growing of system, it is necessary to find a high efficient configuration way. Open and Interoperability feature of IEC61850 makes it possible to model the Feeder Automation in IEC61850.This paper introduced the modeling of FA in IEC61850, including architecture, data, topology and communication. This paper summarized advantage and disadvantage of FA modeling in IEC61850, analyzed the requirement of FA, e.g. network topology, capacity of Switch and so on, and gave some points on how to extend the IEC61850 for basic FA application. This paper concluded that FA modeling in IEC61850 is a good attempt for FA engineering with right extension.
Feeder Automation IEC61850 Modeling Configuration
Zhao Wang Lei Jing Wenxiao Ma
Corporate Research ABB (China) Limited
国际会议
2008 China International Conference on Electricity Distribution (CICED 2008)(2008中国国际供电会议)
广州
英文
1-4
2008-12-10(万方平台首次上网日期,不代表论文的发表时间)