Electrocoagulation for the drinking water treatment of polluted surface water supplies

Electrocoagulation was used for treating micro-polluted raw water. Laboratory scale experiments were conducted with two electrode materials namely, aluminum and iron, Aluminum was selected in these experiments. The optimum working pH was found to be in the neutral condition, allowing raw water to be treated directly without pH adjustment. The given current density and operating time were 50A/m2 and 20 min, the removal efficiency of TOC, Oil and NH3-N were 69.9%, 85.7% and 75% respectively, the removal efficiency of TOC higher than commonly methods.

raw water organic materials electrocoagulation aluminum electrode

Xiangdong LI Qiyan FENG Qingjun MENG Yujie CENG

School of Environment and Spatial Informatics, China University of Mining & Technology, Xuzhou, Jiangsu, China

国际会议

The 2nd International Conference on Bioinformatics and Biomedical Engineering(iCBBE 2008)(第二届生物信息与生物医学工程国际会议)

上海

英文

3713-3716

2008-05-16(万方平台首次上网日期,不代表论文的发表时间)