会议专题

Analysis on the Applicability of Coal Dust Wettability Measurements

The authors of this article analyze the reasons which cause outcomes low repeat rate in ordinary lab testing of coal dust wettability. To eliminate interfering factors in evaluating coal dust wettability measurements such as the air diaphragm, the filling density of the dust in the tube and the hydrophilic property of the glass tube, the authors develop LM-3 device for briquette making of coal dust, composing the equipment of coal dust sample making together with DQ-2.5 digital stress testing machine. The relation between the wettability behavior of the coal dust briquette sample and the samples briquetting pressure P is studied at 0~6.5t/cm2 pressure. The cold briquetting technique improves coal dust wettability measurements, its effect is validated in the lab dust suppression tests using an apparatus MCYZ.

coal dust wettabilty measurement applicability

Li Man Xu Haihong

School of Chemical and Environmental Engineering China University of Mining and Technology (Beijing) Department of Resource and Environmental Engineering North China Institute of Science and Technology

国际会议

The 2nd International Conference on Bioinformatics and Biomedical Engineering(iCBBE 2008)(第二届生物信息与生物医学工程国际会议)

上海

英文

3766-3769

2008-05-16(万方平台首次上网日期,不代表论文的发表时间)