The calculation of positron lifetime in Ni3Al alloy
Superposed-neutral-atom model and the finite-difference method (SNA-FD) are used to calculate the positron lifetime of different sizes and types of defects in Ni3Al alloy. The calculated positron bulk lifetime in Ni3Al agrees well with the experimental results mentioned in literatures. The positron lifetimes of vacancy clusters with the same amount of vacancy but different components are also calculated. The results show that the positron lifetime is different when its components are different. The positron lifetimes of vacancy clusters with a single element but different sizes are also calculated. The result shows that the positron lifetime is almost a constant when its component is only Al vacancy, but the positron lifetime will increase at first and trend to be a constant when its component is only Ni vacancy.
Chen Xiang-Lei Guo Wei-feng Du Huai-Jiang Weng Hui-Mi Ye Bang-Jiao
Laboratory of Nuclear Solid State Physics,University of Science and Technology of China,Hefei 230026 Laboratory of Nuclear Solid State Physics,University of Science and Technology of China,Hefei 230026
国际会议
第九届国际正电子与正电子素国际会议(9th International Workshop on Positron and Positronium Chemistry)(PPC–9)
武汉
英文
99
2008-05-11(万方平台首次上网日期,不代表论文的发表时间)