Basic Ezperiments with Model of Inductive Flowmeter
This article deals the numerical modelling and experimental verification of physi-cal and chemical processes during measurement with inductive flowmeter. There are presented theoretical model and example numerical solution with the comparison of magnetic field mea-surement. The numerical models are based on combined finite element method (FEM) and finite volume method (FVM) of flowmeter electrodes. The model joins magnetic, electric and current field, flow field and chemical nonlinear ion model. Results were compared with accuracy magnetic field measurement inside of body flowmeter.
P.Fiala V.Sadek P.Dohnal T.Bachorec
Department of Theoretical and Experimental Electrical Engineering Brno University of Technology,Kole Department of Languages,Brno University of Technology Udolni 53,602 00 Brno,Czech Republic
国际会议
Progress in Electromagnetics Research Symposium 2008(2008年电磁学研究新进展学术研讨会)(PIERS 2008)
杭州
英文
1-5
2008-03-24(万方平台首次上网日期,不代表论文的发表时间)