Research on Ultrasonic Testing of the Strength of Polymer-modified Thermal Insulation Mortar

With testing ultrasound parameters of the polymer-modified thermal insulation mortar, two functional relationships between the ultrasound parameters and compressive strength will be obtained by applying regression analysis in this paper. The calculation data from the functional relationship would be matched to compressive strength which gained by compression test, and it proves that the ultrasonic testing method has feasibility, and the regression functions can be referenced in practical project.

ultrasonic testing thermal insulation polymer mortar compressive strength ultrasound parameters

Wenbao Zou Weidong Liu Huangjun Xiao Xuewei Zhang

Department of Civil Engineering, College of Urban Construction & Environmental Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China

国际会议

6th Asian Symposium on Polymers in Concrete(第六届亚洲聚合物混凝土国际会议)

上海

英文

71-76

2009-10-29(万方平台首次上网日期,不代表论文的发表时间)