会议专题

Simulated Weld Test of Cadmium Free Contacts

Dynamic contact welding due to arcing in contact bounce are compared for various Cd free contacts in rivet form with a model switch. This included various Ag/SnO2 material of 8 to 14% oxides made by powder metal extrusion as well as internal oxidation. The cumulative plots showed the anti-welding dependence on oxide content and oxide particle size. The various surface microstructure changes due to the arcing and welding events are also examined by scanning electron microscopy and metallurgical examination of rivet cross sections. The surface melting and reactions to redistribute the oxides are found especially with regard to tin oxide and indium oxide layer formations.

cadmium free tin ozide indium ozide dynamic welding

Chi H.Leung

AMI DODUCO Export, Pennsylvania, USA

国际会议

第三届电工产品可靠性与电接触国际会议(The 3rd International Conference on Reliability of Electrical Products and Electrical Contacts)

温州

英文

20-26

2009-10-18(万方平台首次上网日期,不代表论文的发表时间)