会议专题

Investigation on compliance method used for compact tensile specimens in fracture toughness tests of ductile materials

Rotation correction method of unloading compliance for a compact tensile (CT) specimen in the current test standards of ductile fracture toughness Jic (Chinese GB,ASTM and ISO) was under suspicion by tracing its source,and a new rotation correction of the compliance for the CT specimen was given by redefining measured compliance Cm and corrected compliance Cc.The rotation radius R of the specimen was investigated in detail by elasto-plastic finite element analysis,and it was found that the rotation center of the specimen is closed to the crack tip and does not locate at the center of the remaining ligament recommended by the standards.Due to little effect of the material constitutive relationship on R,a polynomial formula between R and a/w was given.Furthermore,a new formula with better accuracy to predict the crack length of the CT specimen was presented.

Ductile fracture toughness Unloading compliance method Compact tensile specimen Compliance rotation correction

Chen Bao Lixun Cai

School of Mechanics and Engineering,Southwest Jiaotong University,Chengdu 610031,P.R.China

国际会议

国际断裂力学2009年会

成都

英文

131-137

2009-10-16(万方平台首次上网日期,不代表论文的发表时间)