会议专题

The influence of ultrasonic and electric spark combining surface treatment for Ti17 alloy on fatigue performances

The wear resistance and hardness of Til 7 alloy were improved by electric spark treatment (EST),while the fatigue life decreased.The surface strengthened by EST,then ultrasonic surface treatment is applied in order to increase fatigue life.The surface morphology was observed by SEM,surface residual stress was analyzed by XRD,tension-tension fatigue test was carried out in the HT-100 fatigue testing machine at 350℃.The results show that surface roughness and residual stress reduce after ultrasonic surface treatment,and fatigue life is about twice the life by only EST,the maximum fatigue life is the specimen with the combining treatment of YG8 electrode EST and ultrasonic treatment.

Ti17 alloy EST Ultrasonic Residual stress Fatigue Surface roughness

Shengru Qiao Lei Jiao Chengyu Zhang Gertsriken Dina Mazanko Vladimir

National Key Laboratory of Thermostructure Composite Materials,Northwestern Polytechnical University Institute for Metal Physics N.A.S.of the Ukraine,Academician Vernadsky Blvd,03680 kyiv-142,Ukraine

国际会议

国际断裂力学2009年会

成都

英文

275-278

2009-10-16(万方平台首次上网日期,不代表论文的发表时间)