Particle on-Line Sampling and Analyses in the High Temperature Industrial Gas of FCCU
By using isokinetic sampling method, the on-line sampling of high-temperature flue gas at inlet and outlet of the third stage cyclone separator in the fluidication catalytic cracking unit (FCCU) was carried out. The solid concentration, size distribution and shape of catalyst particles were obtained by using laser particle size analyzer and particle images analyzer . Then the separation performance of the third stage cyclone separator was calculated and evaluated, which provided guidance for the long-period and safe operation of turbo expander and energy recovery system.
Isokinetic sampling method Particle concentration Size distribution Separation efficience
Ma Yanjie Wang Jianjun Wang Xinghua Jin Youhai
College of Mechanical & Electronic Engineering, China University of Petroleum (East China) No.271, Beier Road, Dongying City, Shandong Province, 257061 P.R.China
国际会议
沈阳
英文
114-116