会议专题

Solid Particle Concentration Measurement Using Pure-Triboelectricity

A new method, pure-triboelectricity, for the particle mass concentration measurement based on the triboelec-tricity and electrostatic induction is developed. The direct rod-shaped sensor is used to measuring the pure-triboelectricity charge and the electrostatic induction charge;the ring sensor is used to measuring the electrostatic induction charge. The pure-triboelectricity can be figured out and the pure-triboelectricity method is eliminated the influence of the electrostatic induction. Through the numerical simulation, the proportion between the electrostatic induction charge measuring by the rod sensor and the electrostatic induction charge measuring by the ring sensor is presented. The particles concentration can be figured out through the pure triboelectricity. Additionally, the sample calibration equipment based on the pure-triboelectricity method is also introduced. Experimental results show the method can on-line measure the solid particle concentration.

Solid particle concentration Pure-triboelectricity Electrostatic induction Triboelectricity

Zhao Yanjun Ma Shuidong Deng li Gong Ruikun Wu Jiangang Wang Shimin

College of Computer and Automatic Control, Hebei Polytechnic University, No 46, Xinhua West Road, Lu Department of Education, Tangshan Normal College, No 156, Jianshe North Road, Lubei District, Tangsh The Key Laboratory of Clean Coal Power Generation and Combustion Technology Ministry of Education, S

国际会议

The 8th International Coference on Measurement and Control of GranularMaterials(第八届国际粉体检测与控制学术会议)(MCGM 2009)

沈阳

英文

328-331

2009-08-27(万方平台首次上网日期,不代表论文的发表时间)