Soft Sensor Model for Mass Flowrate Measurement of Pneumatically Conveyed Solids Using Elbow-Ultrasonic

It is very difficult for the elbow method to accurately measure the particles mass flowrate of pneumatic conveying system. A soft sensor model for the particles mass concentration measurement using the elbow-ultrasonic method is developed. The elbow-ultrasonic method is based on the elbow flowrate measurement method and the Ultrasonic velocity method. The experiment system is built. A nonlinear soft sensor model is established using the BP neural network. The training data samples are the 15 groups of the experiment data and. the soft sensor model is gotten. The other 15 groups of data are used to calibration. The calibration result is indicated that the average error of model is less than 15% . The experiment results prove the validity and reliability of the model. The soft sensor model lowers the calculation complexity and provides an effective solution to online mass flow rate measurement.

Particles mass flowrate Soft sensor BP neural network Elbow-ultrasonic

Zhao Yanjun Yue Shusheng Ma Shuidong Shi Xinyue Gong Ruikun Wang Shimin

College of Computer and Automatic Control, Hebei Polytechnic University, No 46, Xinhua West Road, Lu The Key Laboratory of Clean Coal Power Generation and Combustion Technology Ministry of Education, S

国际会议

The 8th International Coference on Measurement and Control of GranularMaterials(第八届国际粉体检测与控制学术会议)(MCGM 2009)

沈阳

英文

475-478

2009-08-27(万方平台首次上网日期,不代表论文的发表时间)