会议专题

Relation between the Trend of Partial Discharges and Aging Models under AC Voltage

The research work reported in this paper has the aim to contribute in the development of a new physical aging model for damage inception and growth from micro-cavities in polymeric insulating materials subjected to partial discharges (PD) under AC voltage. Aging tests were performed on polyethylene (PE) layered specimens with cylindrical micro-cavities. The PD activity taking place inside the micro-cavities was monitored during the aging process. PD patterns, discharge repetition rates and discharge amplitudes were recorded. Common features can be extracted in the changing trend of PD repetition rate and discharge amplitude. Furthermore, damage growth rate, as well as degradation severity, are inferred through simple statistics.

aging model partial discharge damage growth rate

Le WANG Luigi TESTA Andrea CAVALLINI Gian Carlo MONTANARI

DIE-LIMAT, University of Bologna, Viale Risorgimento, 2-40136 Bologna, Italy

国际会议

第九届电介质材料性能与应用国际会议(The 9th International Conference on Properties and Applications of Dielectric Materials)

哈尔滨

英文

268-271

2009-07-19(万方平台首次上网日期,不代表论文的发表时间)