Formation of Multi-pulse Glow Dielectric Barrier Discharge in Helium at Atmospheric Pressure
Discharge currents were measured on single pulse, multi-pulse glow dielectric barrier discharge (DBD) using high-frequency power supply in helium at atmospheric pressure. The influence of the applied voltage amplitude and frequency, as well as gap distance on multi-pulse glow DBD was discussed and analyzed. Conditions to form multi-pulse glow DBD were proposed. The results show that a higher amplitude of the applied voltage and a lower voltage frequency can be useful to form multi-pulse glow DBD. Moreover, the higher applied voltage is necessary to form multi-pulse glow DBD.
Dielectric barrier discharge multi-pulse glow discharge forming condition
Xiaolei WANG Yanpeng HAO Lin YANG
School of Electric Power, South China University of Technology, Guangzhou, 510640, CHINA
国际会议
哈尔滨
英文
610-613
2009-07-19(万方平台首次上网日期,不代表论文的发表时间)