会议专题

Low Frequency Dielectric Response of Thermally Degraded Epozy-Mica Insulation

Dielectric spectroscopy measurement is essentially a dissipation factor measurement performed at multiple frequencies ranging from few mHz to kHz. Low frequency dielectric spectroscopy measurement has been performed on number of sound and thermally aged epoxy-mica representative laminates and on actual motor coils. Dielectric loss angle, Power Factor, capacitance was measured at frequencies ranging from 1 mHz to 1 kHz. The dielectric response exhibited by of thermally aged epoxy-mica insulation at lower frequencies shows the predominant influence of interfacial polarization on the total dielectric response of epoxy-mica layer.

Epozy-mica dielectric spectroscopy low frequency dielectric response interfacial polarization

B.Nageshwar Rao A.Sudhindra B.Ramachandra

Central Power Research Institute, P.B.No.8066, Prof.Sir.C.V.Raman Road, Bangalore 560 080, India P.E.S College of Engineering Mandya, India

国际会议

第九届电介质材料性能与应用国际会议(The 9th International Conference on Properties and Applications of Dielectric Materials)

哈尔滨

英文

1026-1029

2009-07-19(万方平台首次上网日期,不代表论文的发表时间)