会议专题

Research and Development of Cable Used in Polar Region and Its Quality Control

Investigating in polar region needs the outdoor cable to have good performance of cold resistant. In order to meet the power supply requirements of Antarctic expedition team, a flexible low-temperature resistant outdoor cable was developed. While developing, dielectric analysis was used to choose lower glass-transition temperature material. That ensures the insulation can work in high elasticity stage which improve the cold resistant performance of the material. During the process of manufacture, we improve control precision of conduct diameter and diameter over the cable. Then Statistics Process Control was used to improve the quality of products. Our products have been used for Chinese Antarctic expedition team. In the Antarctic Pole, our products resist the cold weather, did not have any quality problems, and get consumers favorable comment.

cold-resistance cable mathematics statistics Quality Control

Xia yafang Linxin Linfu

Wuxi jiangnan cable co.,Ltd ,china Shanghai Institute of Micro system and Information Technology, Chinese Academy of Sciences Shanghai College of Electrical & Electronic Engineer, Harbin University of Science and Technology

国际会议

第九届电介质材料性能与应用国际会议(The 9th International Conference on Properties and Applications of Dielectric Materials)

哈尔滨

英文

1068-1071

2009-07-19(万方平台首次上网日期,不代表论文的发表时间)