Based on the configuration principles of biological skeletons and sandwich stems, a machine tool column with stiffening ribs inside was designed using structural bionic method. After the lightening effect was verified by finite element simulation, scale-down models of a conventional column and a bionic column were fabricated and tested. Results indicate that the bionic column can reduce the maximum static displacement by 45.9% with 6:13% mass reduction and its dynamic performances is also better with increases in the first two natural frequencies. The structural bionic design is effective in improving the static and dynamic structural performances of high speed machine tools.

column machine tools structural bionic design static displacement dynamic performance

Ling Zhao Wu-yi Chen Jian-feng Ma Yong-bin Yang

School of Mechanical Engineering and Automation, Beihang University, Beijing 100086, P.R.China

国际会议

第二届国际仿生工程会议(The International Conference of Bionic Engineering 2008)(ICBE08)

长春

英文

46-52

2008-10-10(万方平台首次上网日期,不代表论文的发表时间)