INFLUENCE OF THE OIL SECONDARY AIR ON THE FLOW AND COMBUSTION CHARACTERISTICS IN A 300 MWE DOWN-FIRED BOILER

At present, down-fired combustion technology is one of the techniques applied for burning this fuel. However, practical down-fired boiler operation suffers from problems of high carbon content in the fly ash and high NOx emissions. It is difficult to maintain a stable flame, especially when the load is low.1 Up to the 1960s, down-fired boilers were used to burn low-grade coal in Spain.2

Zhengqi Li Feng Ren

School of Energy Science and Engineering Harbin Institute of Technology Harbin, 150001, China