EXPERIMENTAL STUDY ON ADVANCED BIOMASS REBURNING FOR NOz CONTROL

Reburning has been demonstrated in pulverized coal-fired boiler with both coal and natural gas as the reburning fuel. Typically, NO reductions between 50% and 60% are reported without adverse effects on boiler operability. To achieve higher NOx removal efficiency, the new reburning fuel are explored, including super-fine pulverized coal, biomass, liquified petroleum gas, coal water slurry, etc.; otherwise, the advanced reburning (AR) have been being developed that couples basic reburning with the injection of nitrogen agents(i.e., ammonia or urea) and promoter compounds.

Kuihua Han Chunmei Lu Yongzheng Wang Pan Gao Shengli Niu

School of Energy and Power Engineering Shandong University Jinan, 250061, China