SCR Turn-Off Problem Research in Three-Phase Four-Switch PFC
In this paper, a three-phase four-switch power factor correction (PFC) scheme is proposed using two singlephase PFC modules. In this approach, two PFC modules rectify three input currents cooperating with the switching control of SCR. During this control, Some SCR will be turned off in forced case so as to bring the problem that SCR can’t turn off in time. Thereby, it affects the input current THD and converter reliability. This paper will analyze the SCR turn off problem in detail and give some effective solutions. Some experimental results are shown in the paper to verify the solutions are effective.
Yang Li Li Cai Zhiqiang Jiang Jingtao Tan Jianping Ying
Delta Power Electronics Center 238 Minxia Road, Caolu Industry Zone, Pudong, Shanghai, 201209, China
国际会议
The Seventh International PCIM China(第七届电子功率器件、智能传送、电源质量国际研讨会)
上海
英文
153-157
2008-03-18(万方平台首次上网日期,不代表论文的发表时间)