Shunt Active Power Filter for Harmonic and Reactive Compensation in Wind Conversion System

This paper presents an analysis of shunt active power filter (SAPF) used in wind energy system with permanent magnet synchronous generator (PMSG). In current control, supply current control is used instead of load current, i.e., there is no harmonic and reactive current measurement in system. PMSG terminal voltage control is adopted to keep PMSG voltage constant . A new decoupled double synchronous reference frame phase-locked loop (DDSRF-PLL) under different rotor frequency is adopted. This DDSRF-PLL can present a fast, precise and robust detection even under unbalanced and distorted voltage. Experiment results show correction and validity of the control scheme. Index Terms-Shunt active power filter, wind conversion system, permanent magnet synchronous generator, supply current control, phase-locked loop.

Fang Liu Xing Zhang Zhen Xie Po Xu

School of Electrical Engineering and Automation of Hefei University of Technology Hefei,Anhui Province China,230009

国际会议

The Seventh International PCIM China(第七届电子功率器件、智能传送、电源质量国际研讨会)

上海

英文

202-207