会议专题

HIGH TEMPERATURE STOPPED-FLOW STUDIES ON TAR REMOVING

The stopped-flow technique coupling with UV absorbance measurements has been extremely useful for studying reactions that are too fast at high temperature and for detecting reactive intermediates. This paper has described a stopped-flow apparatus that is capable of detecting reactions at high temperature. Toluene shares an important part in solid fuels pyrolysis tar, which is always used as model tar compound to study removing of tar. Furthermore, pyrolysis of toluene at high temperature in the high temperature stopped-flow apparatus has been discussed as examples to study the chemical kinetics mechanism of toluene decomposition.

stopped-flow technique UV absorbance tar pyrolysis

Duan JIA Yionghao LUO Yi CHEN

School of Mechanical and Power Engineering, Shanghai Jiao Tong University, Shanghai 200240, P.R.China

国际会议

第六届煤燃烧国际会议(The 6th International Symposium on Coal Combustion)

武汉

英文

582-585

2007-12-01(万方平台首次上网日期,不代表论文的发表时间)