会议专题

EXPERIMENTAL STUDY OF A LOW-NOX BURNER WITH GAS RE-BURNING UNDER COLD-STATE TEST CONDITIONS

According to some 350MW boiler, constant proportional cold mode experimental bench was established,and mixed ability of re-burning gas and the rotating gas in the furnace was mainly studied. The aerial dynamic field in analogue furnace was studied in terms of gas re-burning by changing the velocity of re-burning gas, and overlay of re-burning gas and NOx in the gas in the furnace was put forward. The results show various re-burning gas velocities influence on the aerial dynamic field. The lower the speed of re-burning gas is ,the earlier the re-burning gas offsets the axis of jet stream, which can’t rip into the center of the rotating gas in the furnace , and on the other side, the re-burning gas penetrates through the rotating gas in the furnace for the re-burning air with excessively high speed. Both of things above can’t well recover the furnace gas flow, thus mixed ability of re-burning gas and gas in the furnace is affected.

boiler low NOz-burner gas re-burning aerial dynamic field overlay

Ming ZHU Zhongxiao ZHANG Tuo ZHOU

College of Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China

国际会议

第六届煤燃烧国际会议(The 6th International Symposium on Coal Combustion)

武汉

英文

955-959

2007-12-01(万方平台首次上网日期,不代表论文的发表时间)