SURGE MECHANISM ANALYSIS AND COUNTERMEASURE OF THE PARALLEL CONNECTION AXIAL-FLOW FAN UNDER HIGH LOAD

This article has explained on the surge mechanism of axial-flow fan, and has analysed the main reason of the parallel connection fan of axial-flow type surged under high load situation. Meanwhile, the paper has introduced actual measure and effect of the surge of some a power plant, and this paper has provided experience in order to avoid the surge happened in other same type fan again.

azial-flow fan surge mechanism countermeasure

Tai LV Wuming DONG Jian ZHANG Yong LI

College of Energy and Mechanical Engineering, Northeast Dianli University, Jilin, China