会议专题

Treatment of high salinity sewage in the modified MUCT Process

With the increased use of seawater, saline wastewater with increasing produced amount and generation sources needs to be treated which was the main reason to decrease the nutrient removal efficiency of normal wastewater treatment plants. In order to find out the removal efficiency of nutrient pollutants of real saline sewage and the influence of salinity shock, a lab-scale nutrient removal activated sludge system, based on the MUCT configuration, was modified to treat 10g/L saline sewage. After long time domestication of microorganism at 10g/L salinity, the TIN(total organic nitrogen) and phosphorus average removal efficiency could be achieved above 87% and 72%.The nutrient removal efficiency was also determined under different salinity shock. The results indicated that the salinity shock influences phosphorus removal efficiency much than nitrogen and organic pollutants, especially increased salinity shock.

modify MUCT saline nitrogen and phosphorous removal salinity shock

Y.Z.Peng L.Ye Y.W.Cui B.Tang

College of Energy and Environmental Engineering, Beijing University of Technology, Beijing, 100022, China

国际会议

第六届中日水环境暨NSFC-JST重大国际合作项目成果交流会

青岛

英文

148-156

2006-10-19(万方平台首次上网日期,不代表论文的发表时间)