The Monitoring of Vibration Effects Caused by Blasting Demolition of the Boiler Room under Complez Environment
In order to ensure the safety of surrounding buildings when the directional blasting demolition of boiler room is carried out. the blasting vibration effect should be monitored. The measured results of blasting vibration velocity and blasting vibration frequency are analyzed, and the results show that: subsection millisecond blasting can control the vibration effect effectively and reduce blasting vibration velocity. The vibration frequency of this boiler room mainly distributes at 5 ~ 20 Hz,which is close to the natural ones of buildings. So, great attention should be paid to it during blasting demolition of buildings.
demolition blasting blasting vibration vibration velocity vibration frequancy vibration monitoring
CHANG Rui XU Ying ZONG Qi
Anhui University of Science and Technology, Huainan, China
国际会议
The Second Asian-Pacific Symposium on Blasting Techniques(第二届亚太地区爆破技术研讨会)
大连
英文
551-555
2009-07-01(万方平台首次上网日期,不代表论文的发表时间)