Biomolecular recognition based on localized surface plasmon resonance of immobilized gold nanorods
A sensitive biosensor based on localized surface plasmon resonance of gold nanorods is fabricated to detect streptavidin. Gold nanorods are immobilized on glass through BSA-biotin instead of chemisorbed method. The detection limit is 1 μM.
Li Jiang Xin Li Qiuqiang Zhan Jun Qian
Centre for Optical and Electromagnetic Research, Zhejiang University, Joint Research Center of Photonics of the Royal Institute ofTechnology (Sweden) and Zhejiang University, Zijingang Campus, Hangzhou, China
国际会议
2008亚洲光纤通讯与光电博览会暨国际会议(Asia Optical Fiber Communication & Optoelectronic Ezposition & Conference)
上海
英文
1-3