MODEL STUDY ON FLOOD DISCHARGE ATOMIZATION OF HYDROPOWER STATIONS ADOPTING ENERGY DISSIPATION BY HYDRAULIC JUMP

The phenomenon of flood discharge atomization is a negative effect brought by the flood discharge of high dams, and it has some certain influences on the dam safety and surrounding environments. The method of large-scale model test is adopted to research the flood discharge atomization of Xiangjiaba Hydropower Station. By use of the prototype observation results of flood discharge atomization of Wantang Hydropower Station which is similar to an energy dissipater. The feedback analysis on the scale effect of atomization models is conducted. The similarity law of atomization quantity is obtained which could be used to predict and evaluate the influences of flood discharge atomization of Xiangjiaba Hydropower Station.

flood discharge atomization energy dissipation by hydraulic jump model test feedback analysis scale effect

Shiqiang Wu Xiufeng Wu Hui Zhou Huiling Chen

Nanjing Hydraulic Research Institute, State Key Laboratory of Hydrology-Water Resources and Hydrauli Nanjing Hydraulic Research Institute, Nanjing, China

国际会议

第16届亚太地区国际水利学大会暨第3届水工水力学国际研讨会(16th IAHR-APD Congress and 3rd Symoposium of IAHR-ISHS)

南京

英文

1743-1749

2008-10-20(万方平台首次上网日期,不代表论文的发表时间)