会议专题

STUDY ON FLOW-INDUCED VIBRATION OF DELIVERY VALVR OF SHIPLOCKS

Flow-induced vibration of delivery valve affects the safe operation of ship locks. The cause of flow-induced vibration of delivery valve and its countermeasures are analyzed and probed in this paper according to the prototype observation data of a few ship locks with a high water head.Flow-induced vibration of delivery valve of ship locks is the coupling result of hydraulic structures with flow, while cavitation is the main cause of violent or harmful vibration of delivery valve. The structural measures of wholely-wrapped arms, streamlined bottom rim and short boom, engineering measures of sudden widening of gallery behind gate and natural aeration of gate lintel, and operational measures of fast or intermittent opening of lock gate are applied to effectively reduce and control vibration in order to prevent harmful vibration.

ship locks delivery valve flow-induced vibration

Shaoze Luo Yaan Hu Baokang Fan Feng Sun

State Key Laboratory of Hydrology, Water Resources and Hydraulic Engineering,Nanjing Hydraulic Research Institute, Nanjing 210029, China

国际会议

第16届亚太地区国际水利学大会暨第3届水工水力学国际研讨会(16th IAHR-APD Congress and 3rd Symoposium of IAHR-ISHS)

南京

英文

2168-2173

2008-10-20(万方平台首次上网日期,不代表论文的发表时间)