会议专题

Design and Test Results of a Front-end ASIC for Radiation Detectors

A front-end ASIC for semiconductor radiation detectors is presented. It is composed of a Charge Sensitive Amplifier (CSA),a pulse shaper,and a Peak Detect and Hold (PDH) circuit. Poly-resistor is used as source degeneration component to reduce the noise of current source in the CSA. The ASIC has been designed in a 0.5um CMOS DPTM technology and tested with Vengy 93000. The gain (PDH excluded) is 78.5mV/fC and the Equivalent Noise Charge (ENC) with detector disconnected is 800-900e. The power dissipation without the output buffer is about 2.6mW.

Zhang Yacong Chen Zhongjian Lu Wengao Ji Lijiu Zhao Baoying

Key Laboratory of Microelectronic Devices and Circuits,Institute of Microelectronics Peking University,100871,P.R.China

国际会议

9th International Conference on Solid-State and Integrated-Circuit Technology(第9届固态和集成电路国际会议)

北京

英文

1717-1720

2008-10-20(万方平台首次上网日期,不代表论文的发表时间)