会议专题

NUMERIAL SIMULATION OF LOW NOz COMBUSTION TECHNOLOGY IN A 410t/h BITUMINOUS COAL-FIRED WALL BOILER

IntroductionNox is one of the main pollutants, which pollutes the environment terribly, so control of its yield and emission has been more and more emphasized. With the promotion of peoples request for lowering pollution of the environment, Nox emission limit index in many countries is more and more low. For example, from 2008. In EU the allowed concentration for power plants over 500 Mwe is 500 mg NO2/Nm3 at 6(%) O2. From 2016 the limit allowed for power plants over 500 Mwe will be 200 mg NO2/Nm3 at 6% O21. This urges to develop much lower Nox emission control technique again 1,2. Domestic new units commonly adopt Low Nox Combustion technology, for example, fuel staging and air staging. But for some old units not adopting technology above, it is an urgent problem need to resolve how to reduce Nox emissions to meet environmental requirements.

Zhengqi Li Zhihong Ge Jianping Jing

School of Energy Science and Engineering, Harbin Institute of Technology,Harbin, 150001, China School of Energy Science and Engineering, Harbin Institute of Technology,Harbin,150001, China

国际会议

The 7th China-Korea Workshop on Clean Energy Technology(第七届中韩清洁能源技术研讨会)

太原

英文

53-54

2008-06-25(万方平台首次上网日期,不代表论文的发表时间)