Application of FOG in Shuibuya High CFRD

Traditional means such as fixed or sliding pitch tester for slab deflection, tension lead horizontal displacement gauge for internal deformation monitoring and pipe type settlement instrument for both horizontal and vertical displacements is still used in CFRD at present. Due to the limits in technology and experience, there are somehow many disadvantages such as interference to construction, difficult for automatic monitoring in construction period and high expenses. Therefore, research in this aspect is of high values both in theoretical and practice. Combining with the application of FOG new technology, and through lab research and the application in actual engineering practice, the application of FOG in dam safety monitoring is possible.

CFRD Deflection Settlement Displacement Safe monitoring FOG Piping

Sun Yi Hu Shiqing Yang Zhanyu Liu Zhaohui

Hubei Qingjiang Hydroelectric Development Co., Ltd, Yichang, Hubei, 443000

国际会议

2005年大坝安全与堤坝隐患探测国际学术研讨会(International Symposium on Dam Safety and Detection of Hidden Troubles of Dams and Dikes)

西安

英文

1-10