Multiple Ionization of Metal Ions in SMIS 75

A Simple Mirror Ion Source with 75GHz pumping(SMIS 75)has been created.The confinement system is a mirror trap with magnetic field in the plug up to 5T.variable length 15-20cm and mirror ratio 3-5.The plasma of metal ions is injected into the trap by a special vacuum arc minigun.Plasma heating is performed by the microwave radiation of a gyrotron(the frequency of 75GHz,power up to 200kW,pulse duration up to 150μs).The results of the experiment have demonstrated substantial multiple ionization of metal ions.For a metal with high melting temperature(Pt),heating shifts the average ion charge from Pt2+ up to Pt7+.Maximum stripped observed ion is Pt10+.Total current of ion beam is about 300mA.

ECR discharge plasma multicharge ions refractory metals

A.V.Vodopyanov S.V.Golubev V.I.Khizhnyak D.A.Mansfeld A.G.Nikolaev E.M.Oks G.Yu.Yushkov

国际会议

The 17th International Workshop on ECR Ion Sources and Their Application(第17届国际ECR离子源研讨会)

兰州

英文

159-161

2006-09-17(万方平台首次上网日期,不代表论文的发表时间)