IN-SITU PH VALUE MONITORING SYSTEM OF CONCRETE PORE SOLUTION

A new auto-logger system device of Open-circuit potential(OCP) was introduced in thispaper, a method of melt-oxidation at high temperature was adopted to fabricate lr/lrOx pHelectrode, the new auto-logger and in-situ pH value monitoring system for use in cementbased porous materials has been invented and tested in solution and in concrete blocks. Theresults show that the lr/IrOx pH electrode have excellent sensing, which follow the Nernst lawwith good linearity in a pH range from 2.0 to 14.0, and have a good long-term stability inalkaline medium. The pH values of concrete pore solution measured by in-situ monitoringsystem is in good quantitative agreement with that determined by pore solution expressionmethod. The In-situ monitoring system can collect the date and supply useful information todurability evaluation of reinforced concrete.

Huaxin Zhou Jiaping Liu Jianfang Sha Ru Mu

Jiangsu Institute of Building Science Co.,Ltd,Nanjing,China Jiangsu Bote New materials Co.,Ltd,Nanjing,China

国际会议

1st International Conference on Microstructure Related Durability of Cementitious Composites(首届与水泥基复合材料耐久性相关的微观结构国际会议)

南京

英文

1431-1438

2008-10-13(万方平台首次上网日期,不代表论文的发表时间)