会议专题

DURABILITY OF A REALKALISATION TREATMENT USING IMPRESSED CURRENT OR GALVANIC ANODES FOR THE REHABILITATION OF REINFORCED CONCRETE STRUCTURES

Carbonation induced corrosion is a major cause of decay of reinforced concretestructures. Electrochemical realkalisation treatment is described as an interesting technique torehabilitate such structures. In this paper,the results of tests on both efficiency and durabilityof two realkalisation treatments (impressed current and galvanic anodes),in accordance withthe CEN/TS 14038-I specification (threshold current density of 200 A.h/m2) are presented.

carbonation corrosion impressed current galvanic anodes

Yun Yun Tong Véronique Bouteiller Elisabeth Marie-Victoire Suzanne Joiret

Laboratoire de Recherche des Monuments Historiques,France Universite P.M.Curie,Laboratoire Interfaces et Systemes Electrochimiques,France Laboratoire de Recherche des Monuments Historiques,France,Universite P.M.Curie,Laboratoire Interface

国际会议

The International Conference on Durability of Concrete Structures(2008年混凝土结构耐久性国际学术会议)

杭州

英文

1324-1330

2008-11-01(万方平台首次上网日期,不代表论文的发表时间)