会议专题

SAFETY ASSESSMENT AND COUNTERMEASURES ON RC STRUCTURE AFTER REINFORCEMENT AND RECONSTRUCTION IN A WASHERY MAIN PLANT

After some RC structures reinforcement and reconstruction in a washery mainplant for technology improvement,in order to meet the demand of safety in production andoperation,field inspection and strengthening redesign were carded on to ensure thereconstruction areas safety. Safety assessments of the inspection area were proposed on thebase of testing and redesign. At the same time,quality evaluation of the strengthening designand construction methods,and some further countermeasures were extracted individually.That can provide a basis for reinforcing or reconstructing the RC structure in washery mainplant.

washery main plant RC structure reinforcement and reconstruction structure inspection redesign and check safety assessment

Shuchun Zhou Yuanzhou Wu Wei Liu Chengming Zhao

School of Architecture and Civil Engineering,CUMT,Xuzhou,Jiangsu 221116,PR China

国际会议

The International Conference on Durability of Concrete Structures(2008年混凝土结构耐久性国际学术会议)

杭州

英文

1045-1050

2008-11-01(万方平台首次上网日期,不代表论文的发表时间)