TIME-FREQUENCY ANALYSIS OF SIGNALS RADIATED FROM CORONA DISCHARGE OF ISOLATED CONDUCTOR
According to the principle of energy storage of capacitor,a simulation system of corona discharge of isolated conductor was given in this paper.The characteristics of the signals radiated from corona discharge were analyzed both in time-domain and frequency-domain.The results indicate that the signals have a damped oscillation waveform under different discharge voltage,and their amplitude increase with the rising of the discharge voltage;the directions of the first pulse of the radiation signals are opposite under different polarities of the discharge voltage;the signals amplitude varies obviously under difrerent values of the charging voltage and the conduction path of the discharge current affects the signalfrequency range obviously.
corona discharge time-frequency analysis isolated conductor
W.D.Liu S.H.Liu L.Wang
Electrostatic and Electromagnetic Protection Research Institute,Mechanical Engineering College,Post Code:050003,Shijiazhuang,Hebei,China
国际会议
The 6th International Conference on Applied Electrostatics(第六届国际静电应用会议)
上海
英文
321-323
2008-11-03(万方平台首次上网日期,不代表论文的发表时间)