会议专题

COMPARISON BETWEEN INJECTION AND RADIATION OF EMP ON CIRCUIT

This paper chooses a type of ignition circuit of fuse as object,and chooses short pulse which rise-time is shorter than Ins as disturbing source.By comparing the experimental results of injection and radiation of pulse on SCR and ignition circuit of fuse,some results are gained that radiation and injection methods are susceptive to different parameters of pulse,such as rise-time and pulse width,and the immunity of SCR against injection pulse cant replace the immunity of SCR in ignition circuit against radiation.A conclusion is drawn that for SCR and ignition circuit,the injection method and radiation method are irrelevant.

electromagnetic pulse(EMP) silicon controlled rectifier(SCR) injection radiation

X.Zhou X.J.Zhang S.P.Wang

Electrostatic and Electromagnetic Protection Research Institute,Shijiazhuang Mechanical Engineering College,97 Heping West Road,Shijiazhuang,050003,Hebei,China

国际会议

The 6th International Conference on Applied Electrostatics(第六届国际静电应用会议)

上海

英文

314-317

2008-11-03(万方平台首次上网日期,不代表论文的发表时间)