TREEING PHENOMENON IN POLYETHYLENE UNDER HIGH FREQUENCY VOLTAGE

In this paper,the electrical treeing phenomenon in polyethylene under AC voltage with frequency ranging from 50 Hz to 100 kHz was studied.With the increase of frequency,the tree initiation voltage(TIV)firstly increases and then decreases after a peak value at 10 kHZ is reached.However,the increase of frequency results in the decrease of the minimum of TIV and the increase of the dispersivity of TIV.There are 4 kinds of tree initiation shape(TIS):branch tree,bush tree,trunk tree and breakdown tree.With the increase of frequency,the kinds of TIS increase and the primary TIS changes from branch tree to bush tree.The influence of frequency on TIV and TIS were discussed.

polyethylene frequency electrical tree tree initiation voltage tree initiation shape

Q.Nie Y.X.Zhou X.L.Xing Y.N.Wang Y.S.Wang

Electrical Engineering Department,Tsinghua University,Post Code:100080,Beijing,China