ENHANCE MECHANICAL PERFORMANCE OF ELECTRORHEOLOGICAL FLUID BY PATTERNING LECTRODES

Sheared electrorheological (ER) fluid under high electric fields usually slippedon electrodes,and weakened the mechanical performance of ER actuators.Thisfailure was usually ascribed to the detachment of particle chains of ER fluids fromelectrodes.Using electrodes with hole patterns,the slip at the interface of chain endand electrode can be effectively suppressed.The suppression is related with holepattern parameters.The reduced slip at the chain end/electrode interface effectivelyenhanced the ER strength both in shearing and compression.

Electrorheological fluid patterned electrode compressive strength slip

M.L.Zhang Y.Tian M.Zhou Y.G,Meng S.Z.Wen

State Key Laboratory of Tdbology,Tsinghua University,Beijing 100084,China

国际会议

第二届国际非均质材料力学会议(The Second International Conference on Heterogeneous Material Mechanics)

安徽黄山

英文

775-779