Researching of the Electrical Parameter Detecting System on Jordan Refiner
There are some disadvantages like that single-function and lower extent of automation in the electrical parameter detecting system of Jordan refiner,so its hard to adapt the system to the demand of the large-scale automatic detecting industry.Depending on the jordan refiner used in paper making,basing on the Labwindows/CVI software to be the host computer and the idea of virtual instrumentation,this devise constructed three-phase detecting system of the electrical parameter which using CS5460A power/energy computation chip for AD converter produced by Cirrus Logic company.The hardware construction and the software designing method are introduced; the concrete plan of enhancing the electrical parameter detecting precision is analyzed.The actual test suggests that the whole system is advantaged in high precision,fast speed,shot exploiting period and deeper extent of automation.
Jordan refiner,electrical Parameter CS5460A Labwindows/CVI
ZHAO JIMIN YANG SHIFENG XU ZHENG JIN SONGTAO
College of Electronic Information and Automation,Tianjin University of Science &Technology
国际会议
第二届国际造纸与环境学术会议(The Second International Papermaking & Environment Conference)
天津
英文
553-556
2008-05-14(万方平台首次上网日期,不代表论文的发表时间)