The Optimization Design for Microwave Wide Band Blackbody Calibration Target
The microwave wide band blackbody calibration target applied for the microwave radiometers pre-launch calibrations are optimized with its electromagnetic parameteremissivity through the radar cross section (RCS) simulations based on the sub-grid finite difference time domain (FDTD)method. The optimization results indict that round wedge is better than the square one,the best ratio for height to bottom radius is 4:1 for the wide band from 10GHz to 26GHz,and the absorbing materials gradual thickness coating and multilayer coating are helpful to guarantee the uniform distribution of surface temperature while keeping a higher emissivity.
Nian Feng Wang Wei
National Key Laboratory of Metrology and Calibration Technology National Key Laboratory of Metrology and Calibration Technology Beijing Institute of Radio Metrology
国际会议
2008 International Conference on Microwave and Millimeter Wave Technology(2008国际微波毫米波技术会议)
南京
英文
1695-1698
2008-04-21(万方平台首次上网日期,不代表论文的发表时间)