会议专题

Assessment of adhesive bond strength in laminated safety glass

Laminated safety glass samples with different levels of adhesive bond strength were manufactured and tested using mechanical guided waves.The results were then compared with those obtained using the commonly used destructive testing method,i.e.,the pummel test method.The imperfect interfaces between the plastic interlayer and the two adjacent glass plates were modeled using a bed of longitudinal and shear springs.The spring constants were estimated using fracture mechanics concepts in conjunction with surface analysis using atomic force microscopy.The guided wave theoretical predictions of adhesion levels(obtained using this multilayered model)were validated using experimental measurements.Results show that this approach is useful in the nondestructive assessment of adhesive bond strength in laminated safety glass.

Laminated safety glass windshields ultrasonics waveguides guided waves acousto-ultrasonics

S. Huo H. Reis

University of Illinois at Urbana-Champaign,Urbana,Illinois,USA

国际会议

The World Forum on Smart Materials and Smart Structures Technology(SMSST07)(2007年世界智能材料与智能结构技术论坛)

重庆·南京

英文

2007-05-01(万方平台首次上网日期,不代表论文的发表时间)