Acoustic Impedance of RLC Load Modulation on a Two Stages Cascade Thermoacoustic Engine
An elementary Cascade ThermoAcoustic Engine (CTAE), consisting of a standing wave stage (1st stage) and a traveling wave stage (2nd stage) in series, has been designed with CRISTA, a simulation program developed at LIMSI. The phase shift between pressure and volume flow rate in the 2nd stage is made by an acoustic RLC load that influences the thermoacoustic parameters in the two stages.The results of this investigation show that for the 2nd stage, there is an optimal acoustic impedance of the RLC load to simultaneously modulate the traveling wave phase and to get higher local impedance for the regenerator. Moreover, the RLC load acoustic impedance can also slightly influence the efficiency of the 1st stage and the transmission loss in the resonator.In later research,a series of experiments will be made to further investigate RLC load according to the above useful simulations.
Xie X J Le Pollès T Bétrancourt A Francois M X
Institut de Physique Nucléaire (IPN),15 rue Georges Clémenceau,Orsay 91405,France HEKYOM SARL,3 Place de la croix Jaque,Saint Aubin 91190,France Laboratoire d Informatique pour la Mécanique et les Sciences de lIngénieur (LIMSICNRS),BP133,Orsay
国际会议
上海
英文
284-289
2008-04-05(万方平台首次上网日期,不代表论文的发表时间)