Reliability Characteristics of Space Stirling Cryocoolers
To study the reliability characteristics of space Stirling cryocoolers,four things were presented in this paper.Firstly, the status and development of space Stirling coolers was introduced. Secondly,failure analysis was done,and the four crucial failure modes affecting coolers long-life running were wear,gaseous contamination,helium leakage and fatigue.Then some experiments were designed and carried to quantitatively analyze the relationship between failure and performance in detail. Finally, according to each failure mechanism, the measures taken to control or minimize its damage were discussed,and some criterions of procedure to guarantee coolers long-term running were given.
Stifling cryocooler Reliability Failure analyses
Liu X G Wu Y N He L
Shanghai Institute of Technical Physics,Chinese Academy of Science,Shanghai 200083,P.R.China
国际会议
上海
英文
259-263
2008-04-05(万方平台首次上网日期,不代表论文的发表时间)